SCH0300 - 0399
| SCH0300 | Wrong number of input fields for prompt RNPG. |
| SCH0301 | Ringing number pickup group number out-of-range (0-255). |
| SCH0302 | Input requires CNUMB package. Action: Contact your technical support group if the system packaging is incorrect. |
| SCH0303 | Input requires CNAME package. Action: Contact your technical support group if the system packaging is incorrect. |
| SCH0304 | Input requires either the CNUMB or the CNAME package. Action: Contact your technical support group if the system packaging is incorrect. |
| SCH0305 | Invalid input for a DIG set. Action: Enter a valid input. |
| SCH0307 | Wrong number of input fields for prompt. |
| SCH0308 | RPE must be removed from data block before OUT or CHG to terminal loop. |
| SCH0310 | Wrong number of input fields for prompt SIGL. |
| SCH0311 | Unable to match input field with stored mnemonics. Action: Refer to administration guide for correct response. |
| SCH0312 | Unacceptable signaling for trunk type. |
| SCH0313 | Wrong number of input fields for prompt ANTK. |
| SCH0314 | Invalid number. |
| SCH0315 | CED (LD 35) cannot be deleted from midnight routines for SL-1 MS. |
| SCH0320 | Wrong number of input fields or prompt STAR. |
| SCH0321 | Only applies to RLR trunks. |
| SCH0324 | MSDL block for the DTI loop cannot be allocated. System memory could be low. Action: Out the DTI loop, free some additional data blocks and try again. |
| SCH0330 | Wrong number of input fields for prompt SUPN. |
| SCH0334 | Incompatible units have been provisioned on the same linecard. Action: Enter the service change data again. |
| SCH0335 | Wrong number of input fields for prompt CMF. |
| SCH0336 | A Service route is needed for routing incoming public network calls. Action: Input a service route number. |
| SCH0337 | Has to be a NI-2 CBC service route with TYPE=COT/DID and SRVC=0. |
| SCH0338 | LND is not defined for this customer. |
| SCH0339 | SNA cannot be specified without LNA. |
| SCH0340 | Class of Service is not allowed for this TRK type. Action: TIE trunks must be IMM start. |
| SCH0341 | Unable to match input field with stored mnemonics. |
| SCH0342 | A group number is not defined for PUA. |
| SCH0343 | VNL cls is acceptable with EAM signaling types only. Action: Set CLS to TRC or NTC. |
| SCH0344 | FNA is not allowed unless hunting is defined. |
| SCH0345 | Incorrect attempt to define CLS = DPIF. Such CLS may only be defined for digital trunks on CDTI2/CSDTI2 cards |
| SCH0346 | DTN not valid for this trunk type. |
| SCH0347 | MFR valid only for CAMA, FGD and M911 trunks. |
| SCH0348 | CAMA (DIP) not valid with route signaling specified. |
| SCH0349 | HTA is not allowed unless Hunting is defined. Action: HNT DN and EHT DN must be defined for HTA/CFTA. |
| SCH0350 | Wrong number of input fields for prompt ANUM. |
| SCH0351 | Attendant number out-of-range (1-15). |
| SCH0352 | Attendant number already in use. |
| SCH0353 | Attendant DN must be defined. |
| SCH0355 | Unable to match input field with stored mnemonics. |
| SCH0356 | CFW or ADL DN size out-of-range. Action: Enter DN length of 4 -31 digits. |
| SCH0357 | Incorrect number of digits entered. Action: Re-enter correct number of digits. |
| SCH0358 | Input is not PAG trunk group access code. |
| SCH0359 | ADL/CFW number exceeds specified length. Action: Enter ADL/CFW DN within configured ADL/CFW DN length size. |
| SCH0360 | Wrong number of input fields for prompt KEY. |
| SCH0361 | Key number out-of-range 0-9 per key/lamp strip, 0-10 for M2012 and M3000, 0-8 for M2009, 0-17 for M2018, 0-5 for M2006. |
| SCH0362 | Unable to match input field with stored mnemonics. |
| SCH0363 | Key function requires lamp key. |
| SCH0364 | Key function requires 5 state lamp: 0 for busy verify. |
| SCH0365 | Speed Call List number out-of-range (0-253). |
| SCH0366 | Speed Call List does not exist, or Hot Line list is not defined for TYPE = HTL. |
| SCH0367 | Member number out-of-range (0-127). |
| SCH0368 | No RNPU group defined for RNP key. |
| SCH0369 | Function conflicts with existing call arrangement. |
| SCH0370 | Directory number conflicts with DIAL 0. |
| SCH0371 | Shorter directory number already exists. |
| SCH0372 | Function not allowed on MIXED directory number. |
| SCH0373 | Loop number does not match DN loop. Multiple loop DN restricted in LD 17. Creation or expansion restricted. |
| SCH0374 | Longer directory number already exists. |
| SCH0375 | DN type conflicts with input DN type. |
| SCH0376 | Function not allowed on private CO line. |
| SCH0377 | VCC or SIG not allowed on multiple appearance DN. |
| SCH0378 | DN already has maximum number (30) of stations attached. |
| SCH0379 | Group number out-of-range (0-99). |
| SCH0380 | AWU requires digit display. |
| SCH0381 | Absorption digit or TDG entry out-of-range (0-9). |
| SCH0382 | Key 0 or key 1 may not be used for AWU. |
| SCH0383 | Number out-of-range (0-3). |
| SCH0384 | Incorrect number of digits (0-999). |
| SCH0385 | Wrong number of input fields. |
| SCH0386 | Number is out-of-range (0-2). |
| SCH0387 | Unable to match input with stored mnemonics. Action: Choose either YES or NO. |
| SCH0389 | Incorrect number of input fields. Action: Re-enter input. |
| SCH0390 | Invalid input for new CRB. |
| SCH0391 | Code restriction number out-of-range (200-999). |
| SCH0392 | Timer not required in this route. |
| SCH0393 | Unable to match input with stored mnemonics. Action: Choose either NO, B1, B2 or B3. |
| SCH0394 | Incorrect number of input fields. |
| SCH0395 | Input overflow. Number greater than 65536. For PNI, input is greater than 32700. |
| SCH0396 | Input entered is out-of-range (Overlay 16). Action: Re-enter input. |
| SCH0397 | Input out-of-range (0-512) (dial delay option). |
| SCH0398 | Unable to match input with stored mnemonics. |